Report No 088213R-ITCEP07V04
Page: 93 of 131
Product Notebook
Test Item Electrostatic Discharge
Test Mode Mode 2
Date of Test 2008/08/27 Test Site No.3 Shielded Room
Item
Amount of
Discharge
Voltage
Required
Criteria
Complied To
Criteria
(A,B,C)
Results
Air Discharge
10
10
+8kV
-8kV
B
B
B
B
Pass
Pass
Contact Discharge
25
25
+4kV
-4kV
B
B
B
B
Pass
Pass
Indirect Discharge
(HCP)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Indirect Discharge
(VCP Front)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Indirect Discharge
(VCP Left)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Indirect Discharge
(VCP Back)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Indirect Discharge
(VCP Right)
50
50
+4kV
-4kV
B
B
A
A
Pass
Pass
Note:
The testing performed is from lowest level up to the highest level as required by standard,
but only highest level is shown on the report.
NR: No Requirement
Meet criteria A: Operate as intended during and after the test
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
EUT stopped operation and could / could not be reset by operator at kV.
No false alarms or other malfunctions were observed during or after the test.
Remark:
The Contact discharges were applied at least total 200 discharges at a minimum of four
test points.