5.4. Test Procedure
The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. The
turn table can rotate 360 degrees to determine the position of the maximum emission level.
The EUT was positioned such that the distance from antenna to the EUT was 10 meters.
The antenna can move up and down between 1 meter and 4 meters to find out the maximum
emission level.
Both horizontal and vertical polarization of the antenna are set on measurement. In order to
find the maximum emission, all of the interface cables must be manipulated on radiated
measurement.
Radiated emissions were invested over the frequency range from 30MHz to1GHz using a
receiver bandwidth of 120kHz. Radiated was performed at an antenna to EUT distance of 10
meters.
5.5. Deviation from Test Standard
No deviation.