Vista de pagina 111
Report No 088213R-ITCEP07V04
Page: 109 of 131
Product Notebook
Test Item Surge
Test Mode Mode 2
Date of Test 2008/08/27 Test Site No.6 Shielded Room
Inject
Line
Polarity Angle
Voltage
kV
Time
Interval
(Second)
Inject
Method
Required
Criteria
Complied
to
Criteria
Result
L-N
±
0 1kV 60 Direct B A PASS
L-N
±
90 1kV 60 Direct B A PASS
L-N
±
180 1kV 60 Direct B A PASS
L-N
±
270 1kV 60 Direct B A PASS
L-PE
±
0 2kV 60 Direct B A PASS
L-PE
±
90 2kV 60 Direct B A PASS
L-PE
±
180 2kV 60 Direct B A PASS
L-PE
±
270 2kV 60 Direct B A PASS
N-PE
±
0 2kV 60 Direct B A PASS
N-PE
±
90 2kV 60 Direct B A PASS
N-PE
±
180 2kV 60 Direct B A PASS
N-PE
±
270 2kV 60 Direct B A PASS
Note:
The testing performed is from lowest level up to the highest level as required by
standard, but only highest level is shown on the report.
Meet criteria A : Operate as intended during and after the test
Meet criteria B : Operate as intended after the test
Meet criteria C : Loss/Error of function
Additional Information
EUT stopped operation and could / could not be reset by operator at kV of
Line
.
No false alarms or other malfunctions were observed during or after the test.