Report No 094061R-ITCEP07V06
Page: 64 of 123
5.6. Test Result
Site : OATS-1 Time : 2009/03/27 - 14:59
Limit : CISPR_B_10M_QP Margin : 6
EUT : Notebook Probe : Site1_CBL6112_10M_0811 - HORIZONTAL
Power : AC 230V/50Hz Note : Mode 1
Frequency
(MHz)
Correct Factor
(dB)
Reading Level
(dBuV)
Measure Level
(dBuV/m)
Margin
(dB)
Limit
(dBuV/m)
Detector Type
1 110.625 13.014 4.000 17.014 -12.986 30.000 QUASIPEAK
2 197.278 10.930 9.200 20.130 -9.870 30.000 QUASIPEAK
3 254.900 14.743 13.000 27.743 -9.257 37.000 QUASIPEAK
4 * 324.000 16.702 15.000 31.702 -5.298 37.000 QUASIPEAK
5 540.000 22.197 7.500 29.697 -7.303 37.000 QUASIPEAK
6 998.217 26.210 5.200 31.410 -5.590 37.000 QUASIPEAK
Note:
1. All Readings below 1GHz are Quasi-Peak, above are performed with peak and/or
average measurements as necessary.
2. " * ", means this data is the worst emission level.
3. Measurement Level = Reading Level + Correct Factor