Report No.: 048L022EI
Page: 9 of 35 Version:1.0
2.5. Test Procedure
The following method of measurement shall apply to both conducted and radiated measurements.
The measurement shall be performed using normal operation of the equipment with modulation, using
the test data sequence, applied. Using a suitable means, the output of the transmitter shall be coupled
to a diode detector; the output of the diode detector shall be connected to the vertical channel of an
oscilloscope; the combination of the diode detector and the oscilloscope shall be capable of faithfully
reproducing the envelope peaks and the duty cycle of the transmitter output signal.
The measurement shall be repeated at the lowest, the middle, and highest frequency of the stated
frequency range.
FHSS equipment shall be made to hop continuously to each of these three frequencies separately.
2.6. Uncertainty
The measurement uncertainty is defined as ± 1.27dB
2.7. Test Specification
According to ETSI EN 300 328:V1.4.1 (2003-04)
2.8. Test Result
The emission from the EUT was below the specified limits. The worst-case emissions are shown in
section 8. The acceptance criterion was met and the EUT passed the test.