Issue Date: 2003-09-25 Page 10 of 42 Report Reference #
E203413-A17-CB-1
IEC 60950
Clause Requirement + Test Result - Remark Verdict
TRF No.: 1950__F UL International Demko A/S TRF originator: FIMKO
2.2 SELV Circuits Pass
2.2.1 General requirements SELV levels are maintained
after single fault condition.
Pass
2.2.2 Voltages under normal conditions (V) ..................:
All accessible voltages are
less than 42.4 Vp or 60 V dc
and are classified as SELV.
Pass
2.2.3 Voltages under fault conditions (V)......................:
Under fault conditions voltages
never exceed 71V peak and
120Vdc and do not exceed
42.4V peak or 60V dc for more
than 0.2 sec.
Pass
2.2.3.1 Separation by double or reinforced insulation
(method 1)
Pass
2.2.3.2 Separation by earthed screen (method 2)
N/A
2.2.3.3 Protection by earthing of the SELV circuit (method
3)
N/A
2.2.4 Connection of SELV circuits to other circuits ........:
SELV circuit and all
interconnected circuits
separated from primary by
Double/Reinforced insulation.
The SELV circuit does not
exceed the SELV limits under
normal and fault conditions.
Pass
2.3 TNV Circuits N/A
2.3.1 Limits
N/A
Type of TNV circuits ...........................................:
-
2.3.2 Separation from other circuits and from accessible
parts
N/A
Insulation employed ...........................................:
-
2.3.3 Separation from hazardous voltages
N/A
Insulation employed ...........................................:
-
2.3.4 Connection of TNV circuits to other circuits
N/A
Insulation employed ...........................................:
-
2.3.5 Test for operating voltages generated externally
N/A