Msi MS-9656 series Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Hardware Msi MS-9656 series. MSI MS-9656 series User Manual [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 81
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
i
3200 Master Series
MS-9656 (V1.X) Server Board
G52-96561X2
Vista de pagina 0
1 2 3 4 5 6 ... 80 81

Indice de contenidos

Pagina 1 - 3200 Master Series

i3200 Master SeriesMS-9656 (V1.X) Server BoardG52-96561X2

Pagina 2 - Technical Support

MS-9656 Server Board1-2Mainboard SpecificationsProcessor- Dual-Core Intel Xeon processor 3000 series, Quad-Core Intel Xeonprocessor 3200 series, Wolfd

Pagina 3 - Safety Instructions

1-3Getting StartedGraphics- XGI Z7 graphics controller- Onboard 16MB Video SDRAMIPMI (Optional)- Hitachi H8S/2168 IPMI microcontrollerConnectorsBack P

Pagina 4 - Micro-Star International

MS-9656 Server Board1-4Mainboard LayoutBATT+JUSB1T: MouseB: Keyboard COM1 JLAN1LANChip XGIZ7 JLAN 2 VGA 2SATA2 SATA4SATA1 SATA3 SATA5SATA6JUSB3JUSB2SY

Pagina 5

2-1Hardware SetupHardware SetupChapter 2This chapter provides you with the information abouthardware setup procedures. While doing the installation,be

Pagina 6

2-2MS-9656 Server BoardQuick Components GuideBack PanelI/O, p.2-10DIMM Slots,p.2-7JPWR1,p.2-9CPU_FAN1,p.2-13FDD1,p.2-11CPU, p.2-3COM2, p.2-15PCI Slots

Pagina 7

2-3Hardware SetupThis mainboard supports dual-core Intel® Xeon® processor 3000 series, quad-coreIntel® Xeon® processor 3200 series, Wolfdale and Yorkf

Pagina 8 - CONTENTS

2-4MS-9656 Server Board1.The CPU socket has a plastic capon it to protect the contact fromdamage. Before you install the CPU,always cover it to protec

Pagina 9 - Getting Started

2-5Hardware Setup6.After confirming the CPU directionfor correct mating, put down theCPU in the socket housing frame.Be sure to grasp on the edge ofth

Pagina 10 - Mainboard Specifications

2-6MS-9656 Server Board10. Align the holes on the mainboardwith the heatsink. Push down thecooler until its four clips getwedged into the holes of the

Pagina 11

2-7Hardware SetupEmptyInstalledMemory64x2=128 pin 56x2=112 pinDDR2240-pin, 1.8VThese DIMM slots are intended for system memory modules.Dual-Channel

Pagina 12 - Mainboard Layout

iiCopyright NoticeThe material in this document is the intellectual property of MICRO-STARINTERNATIONAL. We take every care in the preparation of thi

Pagina 13 - Hardware Setup

2-8MS-9656 Server BoardInstalling Memory Modules1. The memory module has only one notch on the center and will only fit in the rightorientation.2. Ins

Pagina 14 - Quick Components Guide

2-9Hardware Setuppin 12pin 13Important1. Make sure that all connectors are connected to proper power supplies toensure stable operation of the mainboa

Pagina 15 - CPU (Central Processing Unit)

2-10MS-9656 Server BoardBack Panel I/OLED Color LED State ConditionOff LAN link is not established.Left Orange On (steady state) LAN link is establish

Pagina 16 - Important

2-11Hardware SetupFloppy Disk Drive Connector: FDD1This connector supports 360KB, 720KB, 1.2MB, 1.44MB or 2.88MB floppy disk drive.IDE Connector: J_ID

Pagina 17

2-12MS-9656 Server BoardImportantPlease do not fold the Serial ATA cable into 90-degree angle. Otherwise,data loss may occur during transmission.SPI F

Pagina 18

2-13Hardware SetupFan Power Connector:CPU_FAN1, SYS_FAN1/2, FRONT_FAN1, REAR_FAN1The fan power connectors support system cooling fan with +12V. When c

Pagina 19 - Installed

2-14MS-9656 Server BoardFront Panel Connector: JAPP1, JAPP2, JAPP3 (Optional)These are proprietary front panel connectors that provide I2C bus connect

Pagina 20 - Installing Memory Modules

2-15Hardware SetupFront USB Connector: JUSB2, JUSB3, JUSB4This connector, compliant with Intel® I/O Connectivity Design Guide, is ideal for con-nectin

Pagina 21 - Power Supply

2-16MS-9656 Server BoardBMC Connector: J_BOOT1, J_BOOT2, J_IPMB1, J_ICMB1, J1These connectors are used to control the H8 BMC (Baseboard ManagementCont

Pagina 22 - Back Panel I/O

2-17Hardware SetupTPM Connector: JTPM1 (Optional)This connector connects to an optional TPM (Trusted Platform Module). Please referto the TPM security

Pagina 23 - Connector

iiiSafety Instructions1. Always read the safety instructions carefully.2. Keep this User’s Manual for future reference.3. Keep this equipment away fr

Pagina 24

2-18MS-9656 Server BoardVGA Jumper: J_VGA_EN1This jumper is used to enable or disable the onboard VGA controller.Clear CMOS Jumper: J_CMOS1There is a

Pagina 25 - Fan Power Connector:

2-19Hardware SetupPCI (Peripheral Component Interconnect) Express SlotThe PCI Express slot supports the PCI Express interface expansion card.The stand

Pagina 26 - JAPP3 Pin Definition

2-20MS-9656 Server BoardPCI Interrupt Request RoutingThe IRQ, acronym of interrupt request line and pronounced I-R-Q, are hardware linesover which dev

Pagina 27 - Serial Port Connector: COM2

3-1BIOS SetupChapter 3BIOS SetupThis chapter provides information on the BIOS Setupprogram and allows you to configure the system foroptimum use.You

Pagina 28 - Pin Definition

3-2MS-9656 Server BoardEntering SetupImportant1.The items under each BIOS category described in this chapter are undercontinuous update for better sys

Pagina 29 - I2C Bus Connector: J_SMBUS1

3-3BIOS SetupGetting HelpAfter entering the Setup menu, the first menu you will see is the Main Menu.Main MenuThe main menu lists the setup functions

Pagina 30 - BIOS Recovery Jumper: J_BOOT3

3-4MS-9656 Server BoardThe Menu Bar MainUse this menu for basic system configurations, such as time, date etc. AdvancedUse this menu to set up the ite

Pagina 31

3-5BIOS SetupMain AMI BIOS, Processor, System MemoryThese items show the firmware and hardware specifications of your system. Readonly. System TimeThi

Pagina 32 - PCI Interrupt Request Routing

3-6MS-9656 Server BoardAdvanced For mainboards with IPMI chip For mainboards without IPMI chip

Pagina 33 - BIOS Setup

3-7BIOS Setup CPU Configuration Execute Disable Bit CapabilityIntel's Execute Disable Bit functionality can prevent certain classes of malicious&

Pagina 34 - Entering Setup

ivFCC-B Radio Frequency Interference StatementThis equipment has beentested and found to complywith the limits for a Class Bdigital device, pursuant t

Pagina 35 - Load Fail-Safe Defaults

3-8MS-9656 Server Board IDE Configuration SATA#1 Configuration, SATA#2 ConfigurationThese settings specify the operation modes of the SATA ports. Conf

Pagina 36 - The Menu Bar

3-9BIOS Setup[Type] Press PgUp/<+> or PgDn/<-> to select[Manual], [None] or [Auto] type. Note that thespecifications of your drive must ma

Pagina 37

3-10MS-9656 Server Board Onboard LANs Configuration GbE LAN1 (82573) Controller, GbE LAN2 (82566) ControllerThese settings disable/enable the specifie

Pagina 38 - Advanced

3-11BIOS Setup Super IO Configuration Onboard Floppy ControllerThis setting disables/enables the onboard floppy disk drive controller. Serial Port 1 A

Pagina 39

3-12MS-9656 Server Board Hardware Health Configuration (for mainboards without IPMI chip)These items display the current status of all of the monitore

Pagina 40

3-13BIOS Setup APM Configuration Resume On RingAn input signal on the serial Ring Indicator (RI) line (in other words, an incomingcall on the modem) a

Pagina 41

3-14MS-9656 Server Board Event Log Configuration View Event LogPress [Enter] to view the contents of the DMI event log. Mark All Events as ReaddPress

Pagina 42

3-15BIOS Setup IPMI 2.0 Configuration (for mainboards with IPMI chip) Status of BMC, BMC Firmware VersionThese settings show the status of the BMC (Ba

Pagina 43

3-16MS-9656 Server Board BMC Watch Dog Timer ActionThe system watch-dog timer is a hardware timer that generates either an NMI ora reset when the soft

Pagina 44

3-17BIOS Setup Terminal TypeTo operate the system’s console redirection, you need a terminal supportingANSI terminal protocol and a RS-232 null modem

Pagina 45

vWEEE (Waste Electrical and Electronic Equipment) Statement

Pagina 46

3-18MS-9656 Server Board TPM Enable/Disable StatusThis setting displays the TPM enable/disable status. Read only. TPM Owner StatusThis setting shows t

Pagina 47

3-19BIOS Setup USB Mass Storage Device Configuration USB Mass Storage Reset DelayThis setting controls the number of seconds the POST waits for the US

Pagina 48

3-20MS-9656 Server BoardBoot Boot Settings Configuration

Pagina 49

3-21BIOS Setup Quick BootEnabling this setting will cause the BIOS power-on self test routine to skip someof its tests during bootup for faster system

Pagina 50

3-22MS-9656 Server BoardWhen disabled, the ROM BIOS of these host adaptors will not be able to "cap-ture" Interrupt 19. Therefore, you will

Pagina 51

3-23BIOS SetupSecurity Supervisor Password / Change Supervisor PasswordSupervisor Password controls access to the BIOS Setup utility. These settings a

Pagina 52 - Boot Settings Configuration

3-24MS-9656 Server BoardChipset North Bridge Configuration

Pagina 53

3-25BIOS Setup ECC FunctionThis setting enables/disables ECC (Error Correction Code) checking, a methodof checking the integrity of data in DRAM. ECC

Pagina 54

3-26MS-9656 Server BoardExit Save Changes and ExitSave changes to CMOS and exit the Setup Utility. Discard Changes and ExitAbandon all changes and exi

Pagina 55 - Security

A-1Intel ICH9R SATA RAIDIntel ICH9R SATA RAIDAppendix AThis appendix will assist users in configuring and en-abling RAID functionality on platformsThe

Pagina 57

A-2MS-9656 Server BoardICH9R IntroductionImportantThe least number of hard drives for RAID 0, RAID 1 or Matrix mode is 2. Theleast number of hard driv

Pagina 58

A-3Intel ICH9R SATA RAIDBIOS ConfigurationAfter the above message shows, press <Ctrl> and <I> keys simultaneously to enterthe RAID Configu

Pagina 59 - Appendix A

A-4MS-9656 Server Board(1) Create RAID Volume1. Select option 1 “Create RAID Volume” and press <Enter> key. The followingscreen appears. Then in

Pagina 60 - ICH9R Introduction

A-5Intel ICH9R SATA RAID3. In the Disk field, press <Enter> key and the following screen appears. Use<Space> key to select the disks you w

Pagina 61 - BIOS Configuration

A-6MS-9656 Server Board 6.Then the following screen appears for you to confirm if you are sure tocreate the RAID volume. Press <Y> to continue.

Pagina 62 - (1) Create RAID Volume

A-7Intel ICH9R SATA RAID(2) Delete RAID VolumeHere you can delete the RAID volume, but please be noted that all data on RAIDdrives will be lost.Select

Pagina 63

A-8MS-9656 Server Board(3) Reset Disks to Non-RAIDSelect option 3 Reset Disks to Non-RAID and press <Enter> to delete the RAIDvolume and remove

Pagina 64

A-9Intel ICH9R SATA RAIDInstalling DriverInstall Driver in Windows Vista / XP / 2003† New Windows Vista / XP / 2003 InstallationThe following details

Pagina 65

A-10MS-9656 Server Board† Confirming Windows Vista/XP/2003 Driver Installation1. From Windows Vista/XP/2003, open the Control Panel from My Computerf

Pagina 66

A-11Intel ICH9R SATA RAIDInstall Intel Matrix Storage ConsoleThe Intel Application Accelerator RAID Edition driver may be used to operate the harddriv

Pagina 68

A-12MS-9656 Server BoardThe InstallShield Wizard will begin automatically for installation showed as following:Click on the Next button to proceed the

Pagina 69 - Installing Software

A-13Intel ICH9R SATA RAIDAfter reading the license agreement in the following window, click Yes button tocontinue.The window shows the components to b

Pagina 70

A-14MS-9656 Server BoardOnce the installation is complete, the following window appears.The following window appears to show the Readme File Informati

Pagina 71

A-15Intel ICH9R SATA RAIDRAID Migration InstructionsImportantA Create from Existing Disk operation will delete all existing data from theadded disk an

Pagina 72

A-16MS-9656 Server BoardCreate RAID Volume from Existing DiskTo create a RAID volume from an existing disk, choose Action --> Create RAIDVolume fro

Pagina 73 - RAID Migration Instructions

A-17Intel ICH9R SATA RAID(1) Step 1: Configure VolumeHere you can configure the new RAID volume by entering the volume name, selectingthe RAID level a

Pagina 74

A-18MS-9656 Server Boardexpensive (requiring read-in prior to write, in order tobe able to calculate the correct parity information), orsimilar to RAI

Pagina 75

A-19Intel ICH9R SATA RAID(3) Select Member Hard Drive(s)Then select the member disk (the target disk) that you wish to use and then click “--->” to

Pagina 76

A-20MS-9656 Server Board(4) Specify Volume SizeSpecify the amount of available array space to be used by the new RAID volume. Youmay enter the amount

Pagina 77

A-21Intel ICH9R SATA RAID(6) Start MigrationThe migration process may take up to two hours to complete depending on the sizeof the disks being used an

Pagina 78

viiiCONTENTSCopyright Notice...iiTrademark

Pagina 79

A-22MS-9656 Server BoardA RAID 1, RAID 5 or RAID 10 volume is reported as degraded when one of its harddrive members fails or is temporarily disconnec

Pagina 80 - Degraded RAID Array

A-23Intel ICH9R SATA RAID5. Exit Intel RAID Option ROM, and then reboot to Windows system.6. When prompted to rebuild the RAID volume, click 'Ye

Pagina 81

1-1Getting StartedGetting StartedChapter 1Thank you for choosing the 3200 Master Series (MS-9656 V1.X), an excellent server board from MSI.Based on th

Comentarios a estos manuales

Sin comentarios